Summary for Test 2025-04-30-46-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1001165
DEA: 061H6304
EFIS: 0625000097
DIST-CO-RTE-PM06-FRE-6-43.95
Award Date02/03/2025
Closeout Date07/11/2025
Work DescriptionThe scope of work will include culvert replacement, pavement repair, traffic control, and pavement delineation.
Location DescriptionFresno County, Rout I-5 at PM 43.95.
QA Service Level1 (Verified on 04/11/2025)

Sample Information

Sample Taken Date04/30/2025 Sample Unique Key46
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/30/2025
Sample typeAcceptance A brief description of the sampleCement Beams
The quantity of what the sample constitutes30 CY From where was the sample collectedJob Site
First name of sampler or witnessed byJonathon Last name of sampler or witnessed byChaney
Title of samplerTET Telephone number of sampler5592309471
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number2010-007
The truck number from where the sample was collected114 The batch plant ticket number from where the sample was collectedproduction report
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedback of concrete truck. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-04-30-46
DIME Test ID: 2025-04-30-46-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2025-05-07

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: Yes
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 05/03/2025
Identification number: Set 1
Width of specimen: 6 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6.125 inch
Depth of specimen 2: 6.125 inch
Depth of specimen 3: 6.125 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 7120 lb
Maximum load applied 2: 7790 lb
Maximum load applied 3: 7620 lb
Correction Factor: 1
Correction Factor 2: 1
Correction Factor 3: 1
Curing history and apparent moisture condition of the specimen: moist
If specimen was capped, ground or if leather shims were used: leather shims
Defects in specimen, including numbers of beams discarded during test: N/A
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 600 psi
Modulus of rupture 2: 650 psi
Modulus of rupture 3: 640 psi
Modulus of rupture average: 630 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/7/2025