Summary for Test 2025-04-07-1-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 994326 DEA: 051C3604 EFIS: 0512000134 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-217-0.9/1.4 |
| Award Date | 01/31/2023 |
| Closeout Date | Not set |
| Work Description | REPLACE BRIDGE. |
| Location Description | SANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE |
| QA Service Level | 1 (Verified on 10/17/2022) |
Sample Information
| Sample Taken Date | 04/07/2025 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/09/2025 |
| Sample type | Quality Assurance | A brief description of the sample | #8 hoop 4'-8" dia |
| The quantity of what the sample constitutes | 6 LOTS 804 hoops total | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Osiel | Last name of sampler or witnessed by | Ramirez |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 916-767-3535 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L123-024-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 1201036707 |
| Hoop Manufacturer Lot Number(s) | Lots 7 and 12 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #8 |
| Diameter of Hoop | 4'-8" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
| Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2025-04-07-1
DIME Test ID: 2025-04-07-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2025-05-07
Test Results
Number of Samples: 8
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 05/07/2025
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 7 | 8 | 0.79 | 71300 | 90500 | ok necking | Kleinfelder |
| 2 | 2 | 7 | 8 | 0.79 | 72230 | 91500 | ok necking | Kleinfelder |
| 3 | 3 | 7 | 8 | 0.79 | 71970 | 91000 | ok necking | Kleinfelder |
| 4 | 4 | 7 | 8 | 0.79 | 71690 | 90500 | ok necking | Kleinfelder |
| 5 | 1 | 12 | 8 | 0.79 | 71320 | 90500 | ok necking | Kleinfelder |
| 6 | 2 | 12 | 8 | 0.79 | 72050 | 91000 | ok necking | Kleinfelder |
| 7 | 3 | 12 | 8 | 0.79 | 71960 | 91000 | ok necking | Kleinfelder |
| 8 | 4 | 12 | 8 | 0.79 | 71350 | 90500 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/7/2025 ✔