Summary for Test 2017-10-10-2-29
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 210828 DEA: 07290704 EFIS: 0712000076 |
---|---|
DIST-CO-RTE-PM | 07-LA-47-0.9/2.0 |
Award Date | 04/06/2016 |
Closeout Date | 06/25/2019 |
Work Description | RESTORE BRIDGE SEISMIC. |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/03/2016) |
Sample Information
Sample Taken Date | 10/10/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/13/2017 |
Sample type | Quality Assurance | A brief description of the sample | 7/8 -9 x 2-3/4 A325 |
The quantity of what the sample constitutes | 12 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Cummings |
Title of sampler | QA Inspector | Telephone number of sampler | 916-718-7759 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CK Johnson | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S29-223-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 87C275BA30G |
---|---|---|---|
Heat Number(s) | 100887131 | Nut Mfg. Lot Number(s) | 396618A |
Washer Mfg. Lot Number(s) | 304830 | Bolt Specification | A325 |
Bolt Length(s) | 2.75 | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 7/8 | Bolt Mfg. Lot Number | 396618A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-10-10-2
DIME Test ID: 2017-10-10-2-29
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-10-23
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 10/16/2017
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 304830
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: WS WS WS
Size: .875 in
Bolt Length: no data
Measurement Average: 2.11 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/16/2017 ✔