Summary for Test 2025-02-24-16-1

Test performed: CONCLP 4-16

Project Information

Project IdentifiersProject ID: 212861
DEA: 101H2804
EFIS: 1017000190
DIST-CO-RTE-PM10-STA-5-10.7/25.5
Award Date02/06/2024
Closeout DateNot set
Work DescriptionBRIDGE DECK OVERLAY WITH POLYESTER CONCRETE, REPLACE APPROACH SLABS & JOINT SEALS IN STANISLAUS COUNTY ON STATE ROUTE 5 FROM FINK ROAD UC TO KHALSA ROAD UC.
Location DescriptionSTANISLAUS AND MERCED COUNTIES.
QA Service Level1 (Verified on 03/23/2020)

Sample Information

Sample Taken Date02/24/2025 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/25/2025
Sample typeQuality Control A brief description of the sample2 pints 204, chp,8020, z-cure
The quantity of what the sample constitutes100 Totes From where was the sample collectedSource
First name of sampler or witnessed byGilberto Last name of sampler or witnessed byGonzalez
Title of samplerQuality Control Manager Telephone number of sampler7076245467
Laboratory sample identification000153KBP Linked DIME Sample ID000153KBP
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)25-20-291390
Batch number2520291390 Mix number2520291390

Test Details

DIME Sample ID: 2025-02-24-16
DIME Test ID: 2025-02-24-16-1
Testing Lab: Future Labs, LLC
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2025-05-06

Test Results


Input Type: Calculated
Tester's full name: Alex Hamilton
Date of test: 04/29/2025
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 23.04
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 9.1
Volatile content (ASTM D 2369) 30% max: 3.02
Flash point (ASTM D 3828) more than 180 deg F: 212
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: no data
Tack free time, 400 minutes max: 270
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/6/2025