Summary for Test 2025-04-28-51-4
Test performed: AASHTO T324-14Project Information
| Project Identifiers | Project ID: 1000414 DEA: 034H8704 EFIS: 0319000070 |
|---|---|
| DIST-CO-RTE-PM | 03-SUT-99-25.0/26.2 |
| Award Date | 10/09/2024 |
| Closeout Date | Not set |
| Work Description | RDWY EXC, PLACE HMA-A AND CRCP, INSTALL SIGNAL AND LIGHTING. |
| Location Description | SUTTER COUNTY NEAR YUBA CITY FROM 0.6 MILE SOUTH TO 0.6 MILE NORTH OF OSWALD ROAD |
| QA Service Level | 1 (Verified on 07/30/2024) |
Sample Information
| Sample Taken Date | 04/28/2025 | Sample Unique Key | 51 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/28/2025 | Sample type | Production Start-Up |
| A brief description of the sample | 12 Boxes | The quantity of what the sample constitutes | 3/4" HMA w/ 15% RAP |
| From where was the sample collected | Source | First name of sampler or witnessed by | Brad |
| Last name of sampler or witnessed by | McKeehan | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | PSU 25-030 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Hallwood | |
| Transportation Laboratory (TL) Number | C804022 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2025-04-28-51
DIME Test ID: 2025-04-28-51-4
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2025-05-05
Test Results
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 05/02/2025
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 24280
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 24860
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 3.94 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 3.57 mm
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/5/2025 ✔