Summary for Test 2025-01-16-48-6
Test performed: SCAQMD 309-91-Feb93Project Information
| Project Identifiers | Project ID: 994586 DEA: 081C08U4 EFIS: 0822000142 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-10-R134.0/R156.5 |
| Award Date | 06/22/2023 |
| Closeout Date | Not set |
| Work Description | PLACE HMA (TYPE A), JPCP, IMPORTED BORROW, ROADWAY EXCAVATION & CL2 AB |
| Location Description | RIVERSIDE COUNTY FROM 1.1 MILES WEST OF WILEY WELL ROAD OVERCROSSING TO CALIFORNIA/ARIZONA STATE LINE |
| QA Service Level | 1 (Verified on 08/02/2023) |
Sample Information
| Sample Taken Date | 01/16/2025 | Sample Unique Key | 48 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/17/2025 |
| Sample type | Quality Control | A brief description of the sample | 1 gallon can / PPC 1121 RESIN |
| The quantity of what the sample constitutes | 35 Totes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Gilberto | Last name of sampler or witnessed by | Gonzalez |
| Title of sampler | Quality Control Manager | Telephone number of sampler | 7076245467 |
| Laboratory sample identification | 000147KBP | Linked DIME Sample ID | 000147KBP |
| The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Polyester | Mfg. Lot Number(s) | AZ5A00034T |
|---|---|---|---|
| Batch number | AZ5A00034T | Mix number | AZ5A00034T |
Test Details
DIME Sample ID: 2025-01-16-48
DIME Test ID: 2025-01-16-48-6
Testing Lab: Future Labs, LLC
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Test Release Date: 2025-05-01
Test Results
Input Type: Measured
Tester's full name: Alex Hamilton
Date of test: 04/22/2025
Diameter of lid: 154.09 mm
Room Temperature: 75 f
Tare weight: no data
Initial weight: 100.29 grams
Weight at 5 minutes: 100.08 grams
Weight at 10 minutes: 99.89 grams
Weight at 15 minutes: 99.71 grams
Weight at 20 minutes: 99.52 grams
Weight at 25 minutes: 99.35 grams
Weight at 30 minutes: 99.2 grams
Final weight: 99.2 grams
Total weight loss: 1.09 grams
Calculated radius of gallon can lid in cm: 7.705 cm
Lid Factor: 53.617 m^2
Volatile emission: 58.443 grams/m^2
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/1/2025 ✔