Summary for Test 2025-04-28-13-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000369
DEA: 09378804
EFIS: 0919000002
DIST-CO-RTE-PM09-MNO-395-R9.8/R12.6
Award Date08/29/2024
Closeout DateNot set
Work DescriptionPLACE HMA AND ASPHALT BASE, RECYCLE PAVEMENT AND MODIFY ELECTRICAL.
Location DescriptionMONO COUNTY NEAR TOM\\\\\\\\\\\\\\\\'S PLACE FROM 0.5 MILE NORTH OF LOWER ROCK CREEK ROAD TO 1.3 MILES SOUTH OF SOUTH LANDING OVERCROSSING
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date04/28/2025 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing04/28/2025 Sample typeVerification
A brief description of the sample3/4" HMA-A-SP PG58-34M R15 The quantity of what the sample constitutesJMF Verification
From where was the sample collectedSource First name of sampler or witnessed byDerek
Last name of sampler or witnessed byCarrington Title of sampler
Telephone number of sampler7609208313 Laboratory sample identification4573
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite 5 Bridges Plant
Transportation Laboratory (TL) NumberJMF-01 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-04-28-13
DIME Test ID: 2025-04-28-13-2
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-05-01

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 04/28/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4252.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 6356.6 g
Mass of HMA Sample prior to ignition: 2104.4 g
Mass Loss: 106.4 g
Mass of aggregate remaining after ignition: 1998.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.36 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.70 %
General comments (publicly viewable) (Max 1000 characters): JMF-01

Test was verified on 5/1/2025 ✔