Summary for Test 2025-03-19-33-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000416
DEA: 120S1104
EFIS: 1219000091
DIST-CO-RTE-PM12-ORA-22-R0.9/R9.4
Award Date09/04/2024
Closeout DateNot set
Work DescriptionREPLACE CONCRETE BARRIER AND MODIFY LIGHTING SYSTEM.
Location DescriptionORANGE FROM BOLSA CHICA ROAD OVERCROSSING IN GARDEN GROVE TO LEWIS STREET OVERCROSSING IN ORANGE
QA Service Level1 (Verified on 08/05/2024)

Sample Information

Sample Taken Date03/19/2025 Sample Unique Key33
Date that the sample was received by the laboratory/organization performing the testing03/20/2025 Sample typeQuality Assurance
A brief description of the sample4x8 concrete cylinders The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of sampler
Telephone number of sampler Laboratory sample identification25-0115
Linked DIME Sample ID The fabricator/manufacturer/facility nameNATIONAL
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberS59C456T10
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedUnknown
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampledBarrier Light Pedestal 33+02~33+60
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-03-19-33
DIME Test ID: 2025-03-19-33-2
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-04-30

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Dan Morris
Date of test: 04/30/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 54870 lb
Maximum load on cylinder 2: 52750 lb
Maximum load on cylinder 3: 39730 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 42 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 4344.4 psi
Compressive strength of cylinder 2: 4196.5 psi
Compressive strength of cylinder 3: 3160.7 psi
Compressive strength (to nearest 10 psi): 3900 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
25-0115-42Dpdf139.58 KB04/30/20252025-03-19-33-2   Info

Test was verified on 4/30/2025 ✔