Summary for Test 2025-03-07-39-4
Test performed: CTM 214-August 2010Project Information
| Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/07/2025 | Sample Unique Key | 39 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/10/2025 |
| Sample type | Aggregate Prequalification Program | A brief description of the sample | 1x4 |
| The quantity of what the sample constitutes | 100 pounds | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Manuel | Last name of sampler or witnessed by | Robles |
| Title of sampler | Quality Control Representative | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | 2025-03-07-33 | |
| The fabricator/manufacturer/facility name | CEMEX Clayton Aggregates Quarry | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-07-0004 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile @ Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-03-07-39
DIME Test ID: 2025-03-07-39-4
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2025-04-30
Test Results
What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: David Padilla
Date of test: 04/23/2025
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: 0.4 %
Percentage Loss of material retained on ¾ x ½ in. sieve: 2.2 %
Percentage Loss of material retained on ½ x ⅜ in. sieve: 3.9 %
Percentage Loss of material retained on ⅜ in. x #4 sieve: 4.7 %
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 3.2 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/30/2025 ✔