Summary for Test 2025-04-28-14-3

Test performed: AASHTO T30-19

Project Information

Project IdentifiersProject ID: 1000369
DEA: 09378804
EFIS: 0919000002
DIST-CO-RTE-PM09-MNO-395-R9.8/R12.6
Award Date08/29/2024
Closeout DateNot set
Work DescriptionPLACE HMA AND ASPHALT BASE, RECYCLE PAVEMENT AND MODIFY ELECTRICAL.
Location DescriptionMONO COUNTY NEAR TOM\\\\'S PLACE FROM 0.5 MILE NORTH OF LOWER ROCK CREEK ROAD TO 1.3 MILES SOUTH OF SOUTH LANDING OVERCROSSING
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date04/28/2025 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/28/2025
Sample typeVerification A brief description of the sample3/4" Coldfeed & RAP
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byDerek Last name of sampler or witnessed byCarrington
Title of sampler Telephone number of sampler7609208313
Laboratory sample identification4573 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite 5 Bridges Plant Transportation Laboratory (TL) NumberJMF-01
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)00-00-0000
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSample device at Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-04-28-14
DIME Test ID: 2025-04-28-14-3
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2025-05-01

Test Results


Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Calculated
Tester's full name: Derek Carrington
Date of test: 04/28/2025
Cumulative Percent Passing
100 %
100 %
100 %
100 %
100 %
100 %
76 %
55 %
45 %
32 %
21 %
13 %
8.0 %
General comments (publicly viewable) (Max 1000 characters): JMF-01

Test was verified on 5/1/2025