Summary for Test 2025-04-08-27-7

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995482
DEA: 112T36U4
EFIS: 1122000243
DIST-CO-RTE-PM11-SD-5-37.4-52.6
Award Date10/20/2023
Closeout DateNot set
Work DescriptionI-5 NCC SEGMENT 4C
Location DescriptionI-5 in San Diego County at Various Locations from Lomas Santa Fe Drive Undercrossing to 0.2 Mile North of Oceanside Undercrossing
QA Service Level1 (Verified on 11/20/2023)

Sample Information

Sample Taken Date04/08/2025 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/11/2025
Sample typeQuality Assurance A brief description of the samplePSU
The quantity of what the sample constitutes16 boxes From where was the sample collectedSupplier
First name of sampler or witnessed byJesse Last name of sampler or witnessed byGastelum
Title of samplerTET Telephone number of sampler7605628612
Laboratory sample identification25-04-08-27 PSU Linked DIME Sample ID2025-04-08-28
The fabricator/manufacturer/facility nameVulcan Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number220817 CC SJR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-04-08-27
DIME Test ID: 2025-04-08-27-7
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-04-25

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 04/25/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4021.6 g
Mass of the specimen and specimen basket assembly prior to ignition: 5673.4 g
Mass of HMA Sample prior to ignition: 1651.8 g
Mass Loss: 109.0 g
Mass of aggregate remaining after ignition: 1542.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 6.60 %
General comments (publicly viewable) (Max 1000 characters): 3 RAP Burns

Test was verified on 4/25/2025