Summary for Test 2025-04-07-2-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 993446
DEA: 120J34U4
EFIS: 1218000034
DIST-CO-RTE-PM12-ORA-55,55-29.6,R6.4/10.3
Award Date05/27/2022
Closeout DateNot set
Work DescriptionCONSTR BRIDGES, RW, SW, JPCP, HMA PVMT, DRAINAGE AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN IRVINE, SANTA ANA, AND TUSTIN ON ROUTE 5 AT NEWPORT AVENUE UNDERCROSSING AND ON ROUTE 55 FROM 0.4 MILE NORTH OF ROUTE 55/405 SEPARATION TO 0.1 MILE SOUTH OF ROUTE 5/55 SEPARATION
QA Service Level1 (Verified on 06/24/2022)

Sample Information

Sample Taken Date04/07/2025 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/09/2025
Sample typeQuality Assurance A brief description of the sample#6 rebar 3'-0" Lot 1 hoops
The quantity of what the sample constitutes150 pcs. From where was the sample collectedFabricator
First name of sampler or witnessed byJoaquin Last name of sampler or witnessed byMoreno
Title of sampler Telephone number of sampler7146990897
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)378524
Hoop Manufacturer Lot Number(s)378524 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop3'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2025-04-07-2
DIME Test ID: 2025-04-07-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2025-04-25

Test Results


Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 04/25/2025
UTM: NA
Temperature: 0 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11160.4445250103000ok neckingKleinfelder
22160.444288097500ok neckingKleinfelder
33160.4444200100000ok neckingKleinfelder
44160.444347099000ok neckingKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/25/2025