Summary for Test 2025-03-24-87-4

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 212470
DEA: 044A1304
EFIS: 0400001106
COOP: 042718
DIST-CO-RTE-PM04-SON-101-18.5/18.5
Award Date11/17/2023
Closeout DateNot set
Work DescriptionCONSISTS OF MODIFICATION AND RECONSTRUCTION OF THE EXISTING US 101/HEARN AVENUE INTERCHANGE IN SONOMA COUNTY, INCLUDING REPLACING THE EXISTING TWO-LANE HEARN AVENUE OVERCROSSING WITH A NEW OVERCROSSING, AND MODIFYING THE SOUTHBOUND OFF-RAMP IN CITY
Location DescriptionIN SONOMA COUNTY.
QA Service Level1 (Verified on 09/23/2019)

Sample Information

Sample Taken Date03/24/2025 Sample Unique Key87
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/24/2025
Sample typeQuality Assurance A brief description of the samplePCC Agg
The quantity of what the sample constitutes220 CY From where was the sample collectedSource
First name of sampler or witnessed byAnthony Last name of sampler or witnessed byValdez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSuperior Ready Mix Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Canyon Rock
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyer belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-03-24-87
DIME Test ID: 2025-03-24-87-4
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-04-25

Test Results


Number of tests: 1
Input Type: Measured
Tester's full name: Anthony Valdez
Date of test: 03/24/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 52
Sand reading (test 1): 40
Sand equivalent (test 1): 77
Sand equivalent before temperature correction: 77
Sand equivalent after temperature correction: 77
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/25/2025