Summary for Test 2025-04-15-73-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 995085
DEA: 07322904
EFIS: 0716000059
DIST-CO-RTE-PM07-LA-27-0.0/18.6
Award Date11/06/2023
Closeout DateNot set
Work DescriptionREMOVE EXISTING AC PAVEMENT & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET
QA Service Level1 (Verified on 09/11/2023)

Sample Information

Sample Taken Date04/15/2025 Sample Unique Key73
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/15/2025
Sample typeQuality Assurance A brief description of the sampleNative Material
The quantity of what the sample constitutes20 SY From where was the sample collectedJob Site
First name of sampler or witnessed byJareerattana Last name of sampler or witnessed bySirisujarittham
Title of samplerMaterials Tester Telephone number of sampler5625649465
Laboratory sample identification25-1217 Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameBassett and Topanga Canyon Blvd (CA-27) Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)N/A
The fabricator's/manufacturer's product name for the sampleNative The fabricator/manufacturer designation for the sampleCompaction Testing
The plant number A detailed description of where the material sample was collectedJobsite
Where the material sample would have been placed if not sampledJobsite Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-04-15-73
DIME Test ID: 2025-04-15-73-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-04-24

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Jareerattana Sirisujarittham
Date of test: 04/15/2025
Gage No.: 30515
Test No.: C-118
Nuclear By: Jareerattana Sirisujarittham
Non-Bias Plan No.: 5
Depth: 6"
Material No.: Subgrade
Material Type: Native
Impact By: Jareerattana Sirisujarittham
Standard Count Density: 2960 g/cc
Count or Density 1: 4407 g/cc
Count or Density 2: 4562 g/cc
Count or Density 3: 4637 g/cc
Standard Count Moisture: 1075 g/cc
Moisture Count 1: 403 g/cc
Moisture Count 2: 401 g/cc
Moisture Count 3: 436 g/cc
Sum of Count or Density: 13606 g/cc
Average of Count or Density: 4535.33 g/cc
Sum of Moisture Count: 1240 g/cc
Average of Moisture Count: 413.33 g/cc
Calculated Percent Relative Compaction: 92.1 %
Reported Percent Relative Compaction: 92 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/24/2025