Summary for Test 2025-03-21-34-3

Test performed: AASHTO T30-19

Project Information

Project IdentifiersProject ID: 1000314
DEA: 042Y5804
EFIS: 0423000130
DIST-CO-RTE-PM04-SON-1-30.5/32.0
Award Date06/24/2024
Closeout Date09/29/2025
Work DescriptionCOLD PLANE ASPHALT CONCRETE PAVEMENT AND OVERLAY WITH HMA.
Location DescriptionSONOMA COUNTY AT FORT ROSS FROM 2.5 MILES SOUTH OF FORT ROSS ROAD TO 1.0 MILE SOUTH OF FORT ROSS ROAD
QA Service Level1 (Verified on 12/02/2024)

Sample Information

Sample Taken Date03/21/2025 Sample Unique Key34
Date that the sample was received by the laboratory/organization performing the testing03/21/2025 Sample typeProduction Start-Up
A brief description of the sample3/4" HMA-WMA The quantity of what the sample constitutes4 BAGS PER BIN
From where was the sample collectedManufacturer First name of sampler or witnessed byCasey
Last name of sampler or witnessed byFarrington Title of samplerPlant QC
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBoDean Company
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-49-0032
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBatch Plant Hot Bins
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number1 Aggregate Mix Number700SPW16

Test Details

DIME Sample ID: 2025-03-21-34
DIME Test ID: 2025-03-21-34-3
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2025-04-24

Test Results


Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: Yes
Input Type: Calculated
Tester's full name: Anthony Valdez
Date of test: 03/24/2025
Cumulative Percent Passing
100 %
100 %
100 %
100 %
95 %
82 %
54 %
40 %
29 %
21 %
15 %
10 %
6.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/24/2025 ✔