Summary for Test 2025-03-07-39-3

Test performed: CTM 211-May 2010

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/07/2025 Sample Unique Key39
Date that the sample was received by the laboratory/organization performing the testing03/10/2025 Sample typeAggregate Prequalification Program
A brief description of the sample1x4 The quantity of what the sample constitutes100 pounds
From where was the sample collectedManufacturer First name of sampler or witnessed byManuel
Last name of sampler or witnessed byRobles Title of samplerQuality Control Representative
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID2025-03-07-33 The fabricator/manufacturer/facility nameCEMEX Clayton Aggregates Quarry
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-07-0004
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-03-07-39
DIME Test ID: 2025-03-07-39-3
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine
Test Release Date: 2025-04-30

Test Results


How many revolutions are required?: 500 Revolution Test
Input Type: Measured
Tester's full name: Aristeo Flores
Date of test: 03/19/2025
Grading: B
Mass of sample: 5005 grams
Mass retained No. 4 sieve: no data
Mass retained No. 12 sieve: 4344 grams
Percent wear: 13 %
General comments (publicly viewable) (Max 1000 characters): Due to Translab shutdown, material was tested at SRL

Test was verified on 4/30/2025