Summary for Test 2025-04-16-41-2

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 995255
DEA: 041J9604
EFIS: 0414000403
DIST-CO-RTE-PM04-MRN-1-22.8/33.0,45.0/50.5
Award Date02/13/2024
Closeout DateNot set
Work DescriptionCOLD PLANE, RHMA, HMA, MGS, CURB RAMPS, SIDEWALKS, AND CULVERTS.
Location DescriptionMARIN COUNTY IN AND NEAR POINT REYES STATION FROM FIVE BROOKS TO 1.9 MILES NORTH OF CYPRESS ROAD AND IN AND NEAR TOMALES FROM 0.2 MILES SOUTH OF TOMALES TO 4.4 MILES NORTH OF TOMALES
QA Service Level1 (Verified on 10/18/2023)

Sample Information

Sample Taken Date04/16/2025 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/17/2025
Sample typeQuality Assurance A brief description of the sample1/2" RHMA-G-WMA
The quantity of what the sample constitutes4 BOXES From where was the sample collectedManufacturer
First name of sampler or witnessed byCasey Last name of sampler or witnessed byFarrington
Title of samplerPlant QC Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBoDean Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number8 HMA Mix Number10600SPR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-04-16-41
DIME Test ID: 2025-04-16-41-2
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-04-23

Test Results


Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: Anthony Valdez
Date of test: 04/18/2025
Specific Gravity for Sample 1: 2.541
Theoretical maximum density at 25°C (77°F): 2533 kg/m^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/23/2025