Summary for Test 2025-04-16-26-2
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 1001165 DEA: 061H6304 EFIS: 0625000097 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-6-43.95 |
| Award Date | 02/03/2025 |
| Closeout Date | 07/11/2025 |
| Work Description | The scope of work will include culvert replacement, pavement repair, traffic control, and pavement delineation. |
| Location Description | Fresno County, Rout I-5 at PM 43.95. |
| QA Service Level | 1 (Verified on 04/11/2025) |
Sample Information
| Sample Taken Date | 04/16/2025 | Sample Unique Key | 26 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/16/2025 |
| Sample type | Acceptance | A brief description of the sample | Class 2 Aggregate Base |
| The quantity of what the sample constitutes | 1 Bag of Class II Base | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Tomas | Last name of sampler or witnessed by | Silva |
| Title of sampler | MREA | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Granite Coalinga | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0005 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile @ Yard | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-04-16-26
DIME Test ID: 2025-04-16-26-2
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-04-21
Test Results
Number of tests: 1
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 04/17/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 11
Sand reading (test 1): 3.4
Sand equivalent (test 1): 31
Sand equivalent before temperature correction: 31
Sand equivalent after temperature correction: 31
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/21/2025 ✔