Summary for Test 2025-04-14-33-3
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 994785 DEA: 023H32U4 EFIS: 0221000164 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-I5-2.5/R15.9 |
| Award Date | 04/28/2023 |
| Closeout Date | Not set |
| Work Description | Roadway rehabilitation and bridge improvements along I5 in Mount Shasta |
| Location Description | SIS I5 2.5/R15.9 |
| QA Service Level | 1 (Verified on 05/03/2023) |
Sample Information
| Sample Taken Date | 04/14/2025 | Sample Unique Key | 33 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/14/2025 |
| Sample type | Acceptance | A brief description of the sample | RAP |
| The quantity of what the sample constitutes | 2 Bags RAP | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Giuliano | Last name of sampler or witnessed by | Giuntoli |
| Title of sampler | JET | Telephone number of sampler | |
| Laboratory sample identification | D79840B | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis Inc. - Northstate Asphalt (Redding CA) | Transportation Laboratory (TL) Number | 823558 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Tullis, Northstate Asphalt, Redding, CA |
|---|---|---|---|
| Aggregate Size | Aggregate Source | ||
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number |
Combined Gradation Report Information
| Combined Gradation Report Id | Bin Index | Dime Test Id |
|---|---|---|
| 2025-04-4: HMA Aggregates (Size 3/4"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP | 2 | 2025-04-14-33-3 |
Test Details
DIME Sample ID: 2025-04-14-33
DIME Test ID: 2025-04-14-33-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2025-04-17
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: Yes
Input Type: Measured
Tester's full name: Dacota Mei
Date of test: 04/17/2025
| Cumulative Mass Retained | Correction Factor | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 1961.1 grams | ||||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 23.6 grams | 0.0 % | 99 % | ||||
| 235.1 grams | -0.1 % | 88 % | ||||
| 504.3 grams | -1.0 % | 73 % | ||||
| 974.0 grams | -1.0 % | 49 % | ||||
| 1251.0 grams | -0.9 % | 35 % | ||||
| 1446.6 grams | -0.8 % | 25 % | ||||
| 1577.5 grams | -1.2 % | 18 % | ||||
| 1675.1 grams | -0.8 % | 14 % | ||||
| 1744.7 grams | -0.7 % | 10 % | ||||
| 1794.2 grams | -0.6 % | 7.9 % | ||||
| 1797.0 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/17/2025 ✔