Summary for Test 2017-09-27-10-5

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 211968
DEA: 101F0804
EFIS: 1016000116
DIST-CO-RTE-PM10-SJ-4,26-19.75,1.1
Award Date03/15/2017
Closeout Date04/05/2018
Work DescriptionHEAT STRAIGHTENING EXISTING STEEL GIRDERS.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON ON ROUTE 4 AT FARMINGTON ROAD OVERCROSSING AND ON ROUTE 26 AT ROUTE 26/99 SEPARATION.
QA Service Level1 (Verified on 05/16/2017)

Sample Information

Sample Taken Date09/27/2017 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing10/02/2017 Sample typeQuality Assurance
A brief description of the sample A325 Bolt Assembly The quantity of what the sample constitutes74
From where was the sample collectedDistributor First name of sampler or witnessed byJeff
Last name of sampler or witnessed bySmith Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameSt Louis Screw Bolt
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) FormB738717
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0093128, TT0093129
Heat Number(s) Nut Mfg. Lot Number(s)20698-155233
Washer Mfg. Lot Number(s)301263 Bolt SpecificationA325
Bolt Length(s)3", 3.5" Nut SpecificationA563
Washer SpecificationF436 FinishA153 / F2329
Diameter/Size7/8" Bolt Mfg. Lot NumberBG0859, BG0648
Rocap Test Requirement(s) Lubricant Requirements(s)Blue
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2017-09-27-10
DIME Test ID: 2017-09-27-10-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-10-09

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/02/2017
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11AB7387177/8\"70712314.54Nut Proof LoadFred

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 10/2/2017 ✔