Summary for Test 2025-03-26-49-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995119
EFIS: 0319000004
DIST-CO-RTE-PM03-PLA-49-R8.7/R10.6
Award Date12/08/2023
Closeout DateNot set
Work DescriptionCONC BARRIER, JPCP, HMA, RDWY EXC, RCP AND LIGHTING.
Location DescriptionPLACER COUNTY NEAR AUBURN FROM 0.3 MILE SOUTH OF LORENSEN ROAD/FLORENCE LANE TO 0.4 MILE NORTH OF LONE STAR ROAD
QA Service Level1 (Verified on 11/13/2023)

Sample Information

Sample Taken Date03/26/2025 Sample Unique Key49
Date that the sample was received by the laboratory/organization performing the testing04/08/2025 Sample typeQuality Assurance
A brief description of the sample2 Boxes The quantity of what the sample constitutes1/2" HMA w/ 15% RAP
From where was the sample collectedSource First name of sampler or witnessed byMike
Last name of sampler or witnessed byCHITTENDEN Title of sampler
Telephone number of sampler Laboratory sample identificationDaily 25-017
Linked DIME Sample ID2025-03-26-36 The fabricator/manufacturer/facility nameTeichert Hallwood
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-03-26-49
DIME Test ID: 2025-03-26-49-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-04-10

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 04/10/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1549.5 g
Mass Loss: 91.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.63 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.28 %
General comments (publicly viewable) (Max 1000 characters): R1 OBC 5.2%

Test was verified on 4/10/2025 ✔