Summary for Test 2017-09-22-4-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 209384
DEA: 04264094
EFIS: 0400000735
COOP: 042531
DIST-CO-RTE-PM04-,SON--
Award Date01/21/2016
Closeout Date06/03/2020
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 06/03/2020)

Sample Information

Sample Taken Date09/22/2017 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing09/28/2017 Sample typeQuality Assurance
A brief description of the sample2 LCB cylinders The quantity of what the sample constitutes2 LCB cylinder
From where was the sample collectedJob Site First name of sampler or witnessed bytwining
Last name of sampler or witnessed bytwining Title of samplertester
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility namefield
Transportation Laboratory (TL) Number203454 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierUnknown Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberlcb-46
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedna
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedfield Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2017-09-22-4
DIME Test ID: 2017-09-22-4-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-09-29

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bang
Date of test: 09/29/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 18904 lb
Maximum load on cylinder 2: 18555 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 664.2 psi
Compressive strength of cylinder 2: 654.0 psi
Compressive strength (to nearest 10 psi): 660 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 9/29/2017 ✔