Summary for Test 2025-04-08-15-3

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date04/08/2025 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/08/2025
Sample typeIndependent Assurance A brief description of the sample1x 4 Pcc Aggregate
The quantity of what the sample constitutesTwo Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byIGNACIO Last name of sampler or witnessed byARECHIGA
Title of sampler Telephone number of sampler5102077252
Laboratory sample identificationRich_25_ Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex/Fairfield Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-57-0008
The fabricator's/manufacturer's product name for the sample1 x 4 Pcc Aggregate The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt sample
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number1615759 Lot number
Sublot number Aggregate Mix Number1615759

Test Details

DIME Sample ID: 2025-04-08-15
DIME Test ID: 2025-04-08-15-3
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-04-10

Test Results


Number of tests: 1
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 04/08/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5
Sand reading (test 1): 4.2
Sand equivalent (test 1): 84
Sand equivalent before temperature correction: 84
Sand equivalent after temperature correction: 84
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/10/2025