Summary for Test 2024-06-14-110-3
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 995054 DEA: 024H0204 EFIS: 0218000069 |
|---|---|
| DIST-CO-RTE-PM | 02-TEH-36-20.0/39.7 |
| Award Date | 10/23/2023 |
| Closeout Date | 07/03/2025 |
| Work Description | PLACE RHMA AND HMA, CORRECT SEGMENTS, AND REPLACE AC SURFACING. |
| Location Description | TEHAMA COUNTY NEAR RED BLUFF FROM 0.8 MILE EAST OF SALT CREEK BRIDGE TO BAKER ROAD |
| QA Service Level | 1 (Verified on 08/14/2023) |
Sample Information
| Sample Taken Date | 06/14/2024 | Sample Unique Key | 110 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/17/2024 |
| Sample type | Acceptance | A brief description of the sample | 7 boxes of Lime Treated 3/4-inch RHMA-G (PG 64-16 CR) |
| The quantity of what the sample constitutes | 10,000 tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | D79579 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 858498 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 2 |
| Sublot number | 4 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-06-14-110
DIME Test ID: 2024-06-14-110-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2025-04-08
Test Results
Specified number of passes at 12.7 mm: 15000
Specimen Preparation Method:
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 06/25/2024
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 0.96 mm
Maximum impression at 5000 passes (right wheel): 0.85 mm
Average impression at 5000 passes (left/right avg): 0.91 mm
Maximum impression at 10000 passes (left wheel): 1.11 mm
Maximum impression at 10000 passes (right wheel): 1.04 mm
Average impression at 10000 passes (left/right avg): 1.08 mm
Maximum impression at 15000 passes (left wheel): 1.11 mm
Maximum impression at 15000 passes (right wheel): 1.18 mm
Average impression at 15000 passes (left/right avg): 1.15 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters): Nf>15000,
SIP>15000
Test was verified on 4/8/2025 ✔