Summary for Test 2025-03-27-23-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 1000264
DEA: 060W90U4
EFIS: 0623000128
DIST-CO-RTE-PM06-TUL-198,216-R11.6/R11.9,R0.0/2.7
Award Date08/29/2024
Closeout DateNot set
Work DescriptionHMA AND MODIFYING SIGNAL AND LIGHTING SYSTEMS.
Location DescriptionTULARE COUNTY IN AND NEAR VISALIA ON ROUTE 216 FROM 0.2 MILE SOUTH OF LOVERS LANE UNDERCROSSING TO 0.2 MILE EAST OF MCAULIFF STREET AND ON ROUTE 198 FROM 0.1 MILE WEST TO 0.2 MILE EAST OF LOVERS LANE UNDERCROSSING
QA Service Level1 (Verified on 04/15/2024)

Sample Information

Sample Taken Date03/27/2025 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/27/2025
Sample typeQuality Assurance A brief description of the sampleNative Material for Backfill
The quantity of what the sample constitutesTwo Bags From where was the sample collectedJob Site
First name of sampler or witnessed byChris Last name of sampler or witnessed byElias
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationStructure Backfill Sample Linked DIME Sample ID
The fabricator/manufacturer/facility nameNative Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Job Site
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedJob Site
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-03-27-23
DIME Test ID: 2025-03-27-23-2
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-04-07

Test Results


Number of tests: 3
Input Type: Measured
Tester's full name: Chris Elias
Date of test: 03/27/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 13.2
Sand reading (test 1): 1.6
Clay reading (test 2): 12.6
Sand reading (test 2): 1.5
Clay reading (test 3): 13.1
Sand reading (test 3): 1.5
Sand equivalent (test 1): 13
Sand equivalent (test 2): 12
Sand equivalent (test 3): 12
Sand equivalent before temperature correction: 13
Sand equivalent after temperature correction: 13
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/7/2025