Summary for Test 2025-03-28-20-2
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 215425 DEA: 06360244 EFIS: 0613000005 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-99-30.6/35.2 |
| Award Date | 04/26/2021 |
| Closeout Date | 08/31/2026 |
| Work Description | Widen Freeway & Bridge Construction (Concrete Bridge) |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
| Sample Taken Date | 03/28/2025 | Sample Unique Key | 20 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/28/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 HMA-A PG70-10 | The quantity of what the sample constitutes | Sublot |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Martika |
| Last name of sampler or witnessed by | Hall | Title of sampler | JET |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Martin Mariatta | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | NB TUL 99 N of Ave 264 Tagus | |
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 8 |
| Sublot number | 81 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2025-03-28-20
DIME Test ID: 2025-03-28-20-2
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-04-07
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Alexander David
Date of test: 03/28/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7318.5 grams
Mass of oven-dry sample in air for Sample 1: 2561.7 grams
Mass of container filled with the sample and water for Sample 1: 8927.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.690
Theoretical maximum density at 25°C (77°F): 2682 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/7/2025 ✔