Summary for Test 2025-02-19-2-6
Test performed: ASTM A370-20Project Information
| Project Identifiers | Project ID: 1000315 DEA: 07301604 EFIS: 0714000024 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-91,110,710-Var |
| Award Date | 07/31/2024 |
| Closeout Date | Not set |
| Work Description | INSTALL FIBER REINFORCED POLYMER SYSTEM (COLUMN) AND COLUMN CASING. |
| Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 05/13/2024) |
Sample Information
| Sample Taken Date | 02/19/2025 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/12/2025 |
| Sample type | Quality Assurance | A brief description of the sample | A449 ATR |
| The quantity of what the sample constitutes | 116 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Lund |
| Title of sampler | Telephone number of sampler | 8014626352 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Universal Industrial Sales, Inc. | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B390-031-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
|---|---|---|---|
| Heat Number(s) | 58060709 | Nut Mfg. Lot Number(s) | na |
| Washer Mfg. Lot Number(s) | na | Bolt Specification | A449 |
| Bolt Length(s) | 5-1/2"" | Nut Specification | na |
| Washer Specification | na | Finish | HDG |
| Diameter/Size | 1-1/2" | Bolt Mfg. Lot Number | See heat 58060709 |
| Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2025-02-19-2
DIME Test ID: 2025-02-19-2-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2025-04-08
Test Results
Number of Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 04/07/2025
UTM: NA
Temperature: 72 f
| Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 58060709 | 1.5 | 1.405 | 105509 | 125922 | 0 | W Torres |
| 2 | 1B | 58060709 | 1.5 | 1.405 | 105395 | 124847 | 0 | W Torres |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/8/2025 ✔