Summary for Test 2025-03-12-7-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 994875 DEA: 101F1804 EFIS: 1016000077 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-4-R16.0/R19.4 |
| Award Date | 09/20/2023 |
| Closeout Date | Not set |
| Work Description | BRIDGE WORK, CONCRETE BARRIER, AND INSTALL RAMP METER SYSTEM. |
| Location Description | SAN JOAQUIN COUNTY IN STOCKTON AT VARIOUS LOCATIONS FROM 0.3 MILE EAST OF ROUTE 4/5 SEPARATION TO 0.4 MILE WEST OF ROUTE 4/99 SEPARATION |
| QA Service Level | 1 (Verified on 06/14/2023) |
Sample Information
| Sample Taken Date | 03/12/2025 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/24/2025 | Sample type | Quality Assurance |
| A brief description of the sample | Lenton A2 Coupler | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | F |
| Last name of sampler or witnessed by | K | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CMC Steel | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | Erico Lenton | Intermediate Assembler or Fabricator | |
| Rebar Size | #8 | Coupler Model | Lenton A2 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | M0204 | Rebar Heat Number(s) | 4146278 |
| Rebar Size 2 | Coupler Unique ID | ST-17-01 |
Test Details
DIME Sample ID: 2025-03-12-7
DIME Test ID: 2025-03-12-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-03-28
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 03/28/2025
UTM: NA
Halo ID: na
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 8 | 0.79 | 0.009 | 69810 | 88500 | service splice | Kleinfelder |
| 2 | 2 | 1 | 8 | 0.79 | 0000 | 69990 | 88500 | service splice | Kleinfelder |
| 3 | 3 | 1 | 8 | 0.79 | 0000 | 68980 | 87500 | service splice | Kleinfelder |
| 4 | 4 | 1 | 8 | 0.79 | 0000 | 70350 | 89000 | service splice | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/28/2025 ✔