Summary for Test 2025-03-07-1-1
Test performed: ASTM A970-18Project Information
| Project Identifiers | Project ID: 993446 DEA: 120J34U4 EFIS: 1218000034 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-55,55-29.6,R6.4/10.3 |
| Award Date | 05/27/2022 |
| Closeout Date | Not set |
| Work Description | CONSTR BRIDGES, RW, SW, JPCP, HMA PVMT, DRAINAGE AND ELECT SYSTEMS. |
| Location Description | ORANGE COUNTY IN IRVINE, SANTA ANA, AND TUSTIN ON ROUTE 5 AT NEWPORT AVENUE UNDERCROSSING AND ON ROUTE 55 FROM 0.4 MILE NORTH OF ROUTE 55/405 SEPARATION TO 0.1 MILE SOUTH OF ROUTE 5/55 SEPARATION |
| QA Service Level | 1 (Verified on 06/24/2022) |
Sample Information
| Sample Taken Date | 03/07/2025 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/13/2025 |
| Sample type | Quality Assurance | A brief description of the sample | Lot #1 / #8 rebar HRC 120 T-heads |
| The quantity of what the sample constitutes | 20 pcs | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Joaquin | Last name of sampler or witnessed by | Moreno |
| Title of sampler | Telephone number of sampler | 7146990897 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | HRC | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 218924 | Head Manufacturer Lot Number(s) | Lot 1 |
| Rebar Size | #8 | Headed Bar Model Name | 8 rebar HRC 120 T heads |
| Size of Head | Full Size - 9x | Head Connection Type | |
| Head Shape | Square | Rebar Manufacturer | Cascade Steel |
| Head Manufacturer | HRC Fountain Valley | Head Fabricator | Nucor Utah |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | 9FW-17-03 |
Test Details
DIME Sample ID: 2025-03-07-1
DIME Test ID: 2025-03-07-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2025-03-24
Test Results
Number of Headed Bar Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 03/24/2025
UTM: NA
Temperature: 0 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 0.79 | 75360 | 95390 | Ok Necking | Atlas |
| 2 | 1 | 0.79 | 76320 | 96610 | Ok Necking | Atlas |
| 3 | 1 | 0.79 | 76430 | 96750 | Ok Necking | Atlas |
| 4 | 1 | 0.79 | 75830 | 95990 | Ok Necking | Atlas |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/24/2025 ✔