Summary for Test 2024-11-19-57-3
Test performed: CTM 206-October 2011Project Information
| Project Identifiers | Project ID: 994226 DEA: 042K7004 EFIS: 0417000010 COOP: 042895 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-880-R0.0/11.8 |
| Award Date | 07/13/2023 |
| Closeout Date | Not set |
| Work Description | Cold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE) |
| Location Description | ALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
| Sample Taken Date | 11/19/2024 | Sample Unique Key | 57 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/20/2024 | Sample type | Annual Source Testing |
| A brief description of the sample | 3/8 coarse aggregate | The quantity of what the sample constitutes | Ample |
| From where was the sample collected | Source | First name of sampler or witnessed by | Curtis |
| Last name of sampler or witnessed by | Gilbert | Title of sampler | Plant QC |
| Telephone number of sampler | Laboratory sample identification | HW-111924-ST | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan-Pleasanton | |
| Transportation Laboratory (TL) Number | C689529 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0010::CALMAT/PLEASANTON |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-11-19-57
DIME Test ID: 2024-11-19-57-3
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse Aggregate
Test Release Date: 2025-03-21
Test Results
How will the aggregate be used?: portland cement
Input Type: Calculated
Tester's full name: VGopal
Date of test: 03/12/2025
% Water Absorbed: 1.4 %
Bulk Saturated Surface Dry Specific Gravity: 2.66
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/21/2025 ✔