Summary for Test 2024-12-19-37-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993333
DEA: 04264724
EFIS: 0419000068
DIST-CO-RTE-PM04-MRN-101-R20.8/27.1
Award Date04/26/2022
Closeout DateNot set
Work DescriptionCIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location DescriptionMARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date12/19/2024 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/20/2024
Sample typeQuality Assurance A brief description of the sample3/4" hma
The quantity of what the sample constitutes750 TONS From where was the sample collectedManufacturer
First name of sampler or witnessed byMATTHEW Last name of sampler or witnessed byJAMES
Title of samplerQC MANAGER Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDUTRA SAN RAFAEL Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number13
Sublot number17 HMA Mix NumberL210143WMA
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-12-19-37
DIME Test ID: 2024-12-19-37-1
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-03-19

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Cody Cordero
Date of test: 12/20/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2098.4 g
Mass Loss: 134.6 g
Correction Factor (Percent by mass of HMA Specimen): 1.10 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.17 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.15 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/19/2025