Summary for Test 2025-03-08-8-2
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 1000245 DEA: 072XN104 EFIS: 0724000222 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-150- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Retaining wall repair due to landslide emergency at Route 150 in Santa Paula. |
| Location Description | Route 150 in Santa Paula. |
| QA Service Level | 1 (Verified on 04/05/2024) |
Sample Information
| Sample Taken Date | 03/08/2025 | Sample Unique Key | 8 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/08/2025 | Sample type | Acceptance |
| A brief description of the sample | Aggregate Samples | The quantity of what the sample constitutes | 19 CY |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Avo |
| Last name of sampler or witnessed by | Karajian | Title of sampler | Plant Inspector |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Associated Ready Mix - Oxnard | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0054 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Conveyor Belt | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | SL5K450WH | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-03-08-8
DIME Test ID: 2025-03-08-8-2
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-03-31
Test Results
Number of tests: 2
Input Type: Measured
Tester's full name: Avo Karajian
Date of test: 03/10/2025
Temperature correction: 0
Temperature of solution: 75
Clay reading (test 1): 5.1
Sand reading (test 1): 3.8
Clay reading (test 2): 5
Sand reading (test 2): 3.9
Sand equivalent (test 1): 75
Sand equivalent (test 2): 78
Sand equivalent before temperature correction: 77
Sand equivalent after temperature correction: 77
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/31/2025 ✔