Summary for Test 2024-12-09-67-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 995447 DEA: 060X2604 EFIS: 0618000045 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-198-1.6/43.9 |
| Award Date | 03/13/2024 |
| Closeout Date | Not set |
| Work Description | REMOVE, INSTALL, AND REPAIR DRAINAGE FACILITIES. |
| Location Description | TULARE COUNTY IN AND NEAR VISALIA AT VARIOUS LOCATIONS FROM 1.6 MILES EAST OF KINGS COUNTY LINE TO 0.2 MILE WEST OF SEQUOIA NATIONAL PARK BOUNDARY |
| QA Service Level | 1 (Verified on 11/16/2023) |
Sample Information
| Sample Taken Date | 12/09/2024 | Sample Unique Key | 67 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/10/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinders |
| The quantity of what the sample constitutes | Concrete Cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | QC | Last name of sampler or witnessed by | QC |
| Title of sampler | QC | Telephone number of sampler | |
| Laboratory sample identification | 56 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Not Given | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 175457 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | Not Given | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | QC Supplied | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-12-09-67
DIME Test ID: 2024-12-09-67-1
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-03-07
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Chris Elias
Date of test: 01/06/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 66269 lb
Maximum load on cylinder 2: 66177 lb
Maximum load on cylinder 3: 65507 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5272.0 psi
Compressive strength of cylinder 2: 5264.7 psi
Compressive strength of cylinder 3: 5211.4 psi
Compressive strength (to nearest 10 psi): 5250 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/7/2025 ✔