Summary for Test 2025-01-29-1-6
Test performed: ASTM A370-15Project Information
| Project Identifiers | Project ID: 214951 DEA: 120K0234 EFIS: 1214000100 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5-17.1/18.9 |
| Award Date | 09/23/2020 |
| Closeout Date | Not set |
| Work Description | South County Improvement Project (Phase 3 - El Toro/Alicia) WIDEN FREEWAY AND BRIDGES, RECONSTRUCT BRIDGE AND WALLS. |
| Location Description | ORANGE COUNTY IN MISSION VIEJO, LAGUNA HILLS, LAGUNA WOODS AND LAKE FOREST FROM 0.4 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING TO 0.2 MILE NORTH OF EL TORO ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/01/2020) |
Sample Information
| Sample Taken Date | 01/29/2025 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/03/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 1"x1'-2" F1554 grade 36 All threaded rods |
| The quantity of what the sample constitutes | 1 Sample from 10 total | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Osiel | Last name of sampler or witnessed by | Ramirez |
| Title of sampler | LA METS QA Inspector | Telephone number of sampler | (916) 767-3535 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CraneVeyor Corp | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L123-002-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 1000127145 5805574803 211286 | Nut Mfg. Lot Number(s) | 38534-5805574803 |
| Washer Mfg. Lot Number(s) | 211286 / 22331 | Bolt Specification | ASTM F1554 |
| Bolt Length(s) | 14" | Nut Specification | ASTM A563 GR DH |
| Washer Specification | ASTM A568 | Finish | HOT DIP GALVANIZED |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 100012714520 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2025-01-29-1
DIME Test ID: 2025-01-29-1-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2025-03-05
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 03/05/2025
UTM: NA
Temperature: 0 f
| Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 1000127145 | 1 | 0.606 | 57723 | 73597 | 0000 | Atlas |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/5/2025 ✔