Summary for Test 2025-01-29-1-3

Test performed: ASTM B499-09r21

Project Information

Project IdentifiersProject ID: 214951
DEA: 120K0234
EFIS: 1214000100
DIST-CO-RTE-PM12-ORA-5-17.1/18.9
Award Date09/23/2020
Closeout DateNot set
Work DescriptionSouth County Improvement Project (Phase 3 - El Toro/Alicia) WIDEN FREEWAY AND BRIDGES, RECONSTRUCT BRIDGE AND WALLS.
Location DescriptionORANGE COUNTY IN MISSION VIEJO, LAGUNA HILLS, LAGUNA WOODS AND LAKE FOREST FROM 0.4 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING TO 0.2 MILE NORTH OF EL TORO ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/01/2020)

Sample Information

Sample Taken Date01/29/2025 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/03/2025
Sample typeQuality Assurance A brief description of the sample1"x1'-2" F1554 grade 36 All threaded rods
The quantity of what the sample constitutes1 Sample from 10 total From where was the sample collectedFabricator
First name of sampler or witnessed byOsiel Last name of sampler or witnessed byRamirez
Title of samplerLA METS QA Inspector Telephone number of sampler(916) 767-3535
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCraneVeyor Corp Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL123-002-25 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)1000127145 5805574803 211286 Nut Mfg. Lot Number(s)38534-5805574803
Washer Mfg. Lot Number(s)211286 / 22331 Bolt SpecificationASTM F1554
Bolt Length(s)14" Nut SpecificationASTM A563 GR DH
Washer SpecificationASTM A568 FinishHOT DIP GALVANIZED
Diameter/Size1" Bolt Mfg. Lot Number100012714520
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s)

Test Details

DIME Sample ID: 2025-01-29-1
DIME Test ID: 2025-01-29-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2025-03-05

Test Results


Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 02/17/2025
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 211286
Mfg. Lot Number: no data
Finish Coating: Plain
Product Markings: no data
Size: 1.0 in
Bolt Length: no data
Measurement Average: 2.8 mils
General comments (publicly viewable) (Max 1000 characters): Atlas Technical Consultants

Test was verified on 3/5/2025