Summary for Test 2025-02-20-31-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 1000115
DEA: 060Y7604
EFIS: 0619000024
DIST-CO-RTE-PM06-FRE-L5506,L5725-
Award Date05/08/2024
Closeout DateNot set
Work DescriptionMODIFICATION OF ELECTRICAL SYSTEM.
Location DescriptionFRESNO COUNTY IN FRESNO AT THE WEST AVENUE MAINTENANCE STATION 1283 NORTH WEST AVENUE AND AT THE DISTRICT OFFICE 1352 WEST OLIVE AVENUE
QA Service Level1 (Verified on 02/26/2024)

Sample Information

Sample Taken Date02/20/2025 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/20/2025
Sample typeAcceptance A brief description of the sample1/2 HMA ColdFeed
The quantity of what the sample constitutes20 tons From where was the sample collectedManufacturer
First name of sampler or witnessed byNoah Last name of sampler or witnessed byHunt
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Ashlan Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Vulcan Materials
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedColdfeed Chute
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number1
Sublot number1 Aggregate Mix Number

Test Details

DIME Sample ID: 2025-02-20-31
DIME Test ID: 2025-02-20-31-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2025-03-04

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Tomas Silva
Date of test: 02/20/2025
Cumulative Percent Passing
%
100 %
100 %
100 %
96 %
89 %
58 %
39 %
28 %
20 %
14 %
8 %
4.4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/4/2025