Summary for Test 2025-02-20-2-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 212720 DEA: 07291404 EFIS: 0712000094 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-1-55-58 |
| Award Date | 02/18/2021 |
| Closeout Date | Not set |
| Work Description | TRANCAS CREEK BRIDGE REPLACEMENT |
| Location Description | IN LOS ANGELES IN CITY OF MALIBU AT TRANCAS CREEK BRIDGE (53-0027). |
| QA Service Level | 1 (Verified on 04/02/2021) |
Sample Information
| Sample Taken Date | 02/20/2025 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/26/2025 |
| Sample type | Quality Assurance | A brief description of the sample | #10 HRC 500/510 Couplers |
| The quantity of what the sample constitutes | 32825 lbs | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Henry | Last name of sampler or witnessed by | Arredondo |
| Title of sampler | CALTRANS QA INSPECTOR | Telephone number of sampler | 5623329603 |
| Laboratory sample identification | TP-17-03 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Headed Reinforcement Corp, Fountain Valley, CA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L166-004-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC Steel Arizona |
| Coupler Manufacturer | Headed Reinforcement Corporation Fountain Val | Intermediate Assembler or Fabricator | Stephen Luna |
| Rebar Size | #10 | Coupler Model | HRC 500/510 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 74135330, 74133720 | Rebar Heat Number(s) | 9004756 |
| Rebar Size 2 | Coupler Unique ID | TP-17-03 |
Test Details
DIME Sample ID: 2025-02-20-2
DIME Test ID: 2025-02-20-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-03-04
Test Results
Number of Samples: 4
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 03/01/2025
UTM: NA
Halo ID: 000
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 9004756 | 10 | 1.27 | 0.0020 | 121010 | 95283 | Lot 2 | Miguel Baltazar |
| 2 | 2A | 9004756 | 10 | 1.27 | 000 | 120940 | 95228 | Lot 2 | Miguel Baltazar |
| 3 | 3A | 9004756 | 10 | 1.27 | 000 | 121210 | 95441 | Lot 2 | Miguel Baltazar |
| 4 | 4A | 9004756 | 10 | 1.27 | 000 | 121290 | 95504 | Lot 2 | Miguel Baltazar |
General comments (publicly viewable) (Max 1000 characters): Atlas Technical Consultants
Test was verified on 3/4/2025 ✔