Summary for Test 2024-12-10-78-6

Test performed: AASHTO T48-18

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date12/10/2024 Sample Unique Key78
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/14/2025
Sample typeVerification A brief description of the sampleTank 3410
The quantity of what the sample constitutes1 of 1 From where was the sample collectedManufacturer
First name of sampler or witnessed byMolly Last name of sampler or witnessed byGibney
Title of sampler Telephone number of sampler
Laboratory sample identificationAC-270-3110 Linked DIME Sample ID2024-12-10-70
The fabricator/manufacturer/facility nameRedding, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number3410
Time of sample HMA Supplier
Certified Asphalt SupplierVSS Emutech - Redding CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-12-10-78
DIME Test ID: 2024-12-10-78-6
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2025-03-04

Test Results


Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Measured
Tester's full name: Atlas
Date of test: 02/25/2025
Observed Flash Point: 310 C
Ambient Barometric Pressure: 615 mmHg
Cleveland Open-Cup Flash Point in Celsius: 315 C
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/4/2025