Summary for Test 2024-11-20-24-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 214486
DEA: 080K1224
EFIS: 0815000244
DIST-CO-RTE-PM08-SBD-15-R28.6/37.5
Award Date09/24/2021
Closeout Date11/03/2025
Work DescriptionREHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT
Location DescriptionSAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date11/20/2024 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/22/2024
Sample typeQuality Assurance A brief description of the sample6X12
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byFRANCISCO Last name of sampler or witnessed byRUVALCABA
Title of samplertet Telephone number of sampler
Laboratory sample identification1042-112024 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCEMEX Transportation Laboratory (TL) Number1042-112024
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberRRM21010
The truck number from where the sample was collectedNA The batch plant ticket number from where the sample was collected2
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedNB I15 JOSHUA ST ON RAMP STA 268 TO 270 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-11-20-24
DIME Test ID: 2024-11-20-24-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-02-25

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 12/31/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Average diameter of cylinder 3: 5.98 in
Maximum load on cylinder 1: 216880 lb
Maximum load on cylinder 2: 206820 lb
Maximum load on cylinder 3: 212110 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 42 days
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Cross sectional area of cylinder 3: 28.09 in^2
Compressive strength of cylinder 1: 7720.9 psi
Compressive strength of cylinder 2: 7362.8 psi
Compressive strength of cylinder 3: 7551.1 psi
Compressive strength (to nearest 10 psi): 7540 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/25/2025