Summary for Test 2024-10-03-131-1
Test performed: AASHTO T335-09r13Project Information
| Project Identifiers | Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for storing JMF sample data |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 10/03/2024 | Sample Unique Key | 131 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/04/2024 |
| Sample type | Verification | A brief description of the sample | Combined Untreated 3/8-inch Aggregate |
| The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Ward | Last name of sampler or witnessed by | Jenkins |
| Title of sampler | Not set | Telephone number of sampler | Not set |
| Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
| The fabricator/manufacturer/facility name | Dig It Construction — Sierra Cascade Aggregate and Asphalt Products (Chester, CA) | Transportation Laboratory (TL) Number | Not set |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-32-0002::Chester Pit 1 (Chester, CA) |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Not set | The fabricator/manufacturer designation for the sample | Not set |
| The plant number | Not set | A detailed description of where the material sample was collected | Laboratory-Batched from Untreated Sized Aggregate Stockpile samples |
| Where the material sample would have been placed if not sampled | Not set | Primary Aggregate Nominal Size | 3/8 inch |
| The concrete mix design number | Lot number | Not set | |
| Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2024-10-03-131
DIME Test ID: 2024-10-03-131-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2025-02-25
Test Results
Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Josh Ferency
Date of test: 10/22/2024
Percentage of fractured, coarse, 2 faced particles tested: 99 %
Percentage of fractured, coarse, 1 faced particles tested: 99 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters): Submitted from JMF - Ward Jenkins
Test was verified on 2/25/2025 ✔