Summary for Test 2025-02-21-8-1
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 1000285 DEA: 042Q4604 EFIS: 0419000015 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-101-0.8,3.4 |
| Award Date | 08/28/2024 |
| Closeout Date | 06/18/2026 |
| Work Description | BRIDGE RAIL REPLACEMENT. |
| Location Description | THE CITY AND COUNTY OF SAN FRANCISCO AT THIRD STREET UNDERCROSSING AND AT TWENTY THIRD STREET OVERCROSSING. |
| QA Service Level | 1 (Verified on 07/15/2024) |
Sample Information
| Sample Taken Date | 02/21/2025 | Sample Unique Key | 8 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/21/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 1" X #4 Coarse Agg | The quantity of what the sample constitutes | 9 cy |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Leonardo |
| Last name of sampler or witnessed by | Mendoza | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | HW-PCC-022125 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CEMEX-SF | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | ::PORT MCNEIL QUARRY(ORCA AGGREGATE) |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile @ Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | 1521431 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-02-21-8
DIME Test ID: 2025-02-21-8-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2025-02-24
Test Results
What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Leonardo Mendoza
Date of test: 02/24/2025
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 100 % | ||||||
| 100 % | ||||||
| 79 % | ||||||
| 33 % | ||||||
| 24 % | ||||||
| 12 % | ||||||
| 1 % | ||||||
General comments (publicly viewable) (Max 1000 characters): Test passed
Test was verified on 2/24/2025 ✔