Summary for Test 2025-02-19-5-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000115 DEA: 060Y7604 EFIS: 0619000024 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-L5506,L5725- |
| Award Date | 05/08/2024 |
| Closeout Date | Not set |
| Work Description | MODIFICATION OF ELECTRICAL SYSTEM. |
| Location Description | FRESNO COUNTY IN FRESNO AT THE WEST AVENUE MAINTENANCE STATION 1283 NORTH WEST AVENUE AND AT THE DISTRICT OFFICE 1352 WEST OLIVE AVENUE |
| QA Service Level | 1 (Verified on 02/26/2024) |
Sample Information
| Sample Taken Date | 02/19/2025 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/19/2025 |
| Sample type | Acceptance | A brief description of the sample | 1/2 HMA |
| The quantity of what the sample constitutes | 64 tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Jonathon | Last name of sampler or witnessed by | Chaney |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | vulcan materials | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2025-02-19-5
DIME Test ID: 2025-02-19-5-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-02-20
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 02/19/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3973.6 g
Mass of the specimen and specimen basket assembly prior to ignition: 5580.4 g
Mass of HMA Sample prior to ignition: 1606.8 g
Mass Loss: 76.8 g
Mass of aggregate remaining after ignition: 1530.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.12 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.66 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/20/2025 ✔