Summary for Test 2025-02-19-5-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000115
DEA: 060Y7604
EFIS: 0619000024
DIST-CO-RTE-PM06-FRE-L5506,L5725-
Award Date05/08/2024
Closeout DateNot set
Work DescriptionMODIFICATION OF ELECTRICAL SYSTEM.
Location DescriptionFRESNO COUNTY IN FRESNO AT THE WEST AVENUE MAINTENANCE STATION 1283 NORTH WEST AVENUE AND AT THE DISTRICT OFFICE 1352 WEST OLIVE AVENUE
QA Service Level1 (Verified on 02/26/2024)

Sample Information

Sample Taken Date02/19/2025 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/19/2025
Sample typeAcceptance A brief description of the sample1/2 HMA
The quantity of what the sample constitutes64 tons From where was the sample collectedManufacturer
First name of sampler or witnessed byJonathon Last name of sampler or witnessed byChaney
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namevulcan materials Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number1
Sublot number1 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-02-19-5
DIME Test ID: 2025-02-19-5-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-02-20

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 02/19/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3973.6 g
Mass of the specimen and specimen basket assembly prior to ignition: 5580.4 g
Mass of HMA Sample prior to ignition: 1606.8 g
Mass Loss: 76.8 g
Mass of aggregate remaining after ignition: 1530.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.12 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.66 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2025