Summary for Test 2017-09-13-4-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 211967 DEA: 101E8904 EFIS: 1016000093 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-5-26.5/27.0 |
| Award Date | 03/02/2017 |
| Closeout Date | 01/24/2020 |
| Work Description | REPAIR BRIDGE CROSSFRAMES. |
| Location Description | SAN JOAQUIN COUNTY IN STOCKTON AT STOCKTON CHANNEL VIADUCT |
| QA Service Level | 1 (Verified on 07/24/2017) |
Sample Information
| Sample Taken Date | 09/13/2017 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/15/2017 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Bolts |
| The quantity of what the sample constitutes | 74 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
| Title of sampler | ASI | Telephone number of sampler | 510-693-3545 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Cordova Bolt | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L02-062-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 304 17 06 |
|---|---|---|---|
| Heat Number(s) | NF12204448 | Nut Mfg. Lot Number(s) | 385053B |
| Washer Mfg. Lot Number(s) | 0317 495 | Bolt Specification | A325 |
| Bolt Length(s) | 7" | Nut Specification | A563 DH |
| Washer Specification | F1554 | Finish | HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 323540A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | yes | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-09-13-4
DIME Test ID: 2017-09-13-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-09-27
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/19/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 4A | NA | 1\" | 93362 | 415.29 | Nut Proof | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Partner Data Point FileTest was verified on 9/20/2017 ✔