Summary for Test 2017-09-13-3-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 211967 DEA: 101E8904 EFIS: 1016000093 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-5-26.5/27.0 |
| Award Date | 03/02/2017 |
| Closeout Date | 01/24/2020 |
| Work Description | REPAIR BRIDGE CROSSFRAMES. |
| Location Description | SAN JOAQUIN COUNTY IN STOCKTON AT STOCKTON CHANNEL VIADUCT |
| QA Service Level | 1 (Verified on 07/24/2017) |
Sample Information
| Sample Taken Date | 09/13/2017 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/15/2017 | Sample type | Quality Assurance |
| A brief description of the sample | A325 Bolts | The quantity of what the sample constitutes | 54 |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Kevin |
| Last name of sampler or witnessed by | Churchill | Title of sampler | ASI |
| Telephone number of sampler | 510-693-3545 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Cordova Bolt |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | L02-062-17 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 304 17 05 |
|---|---|---|---|
| Heat Number(s) | DL15104555 | Nut Mfg. Lot Number(s) | 385053B |
| Washer Mfg. Lot Number(s) | 0317 495 | Bolt Specification | A325 |
| Bolt Length(s) | 3-3/4 | Nut Specification | A563 DH |
| Washer Specification | F1554 | Finish | HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 367457A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | yes | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2017-09-13-3
DIME Test ID: 2017-09-13-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-09-27
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/19/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 3A | NA | 1\" | 94520 | 420.45 | Nut Proof | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Partner Data Point FileTest was verified on 9/20/2017 ✔