Summary for Test 2025-01-17-16-2
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/17/2025 | Sample Unique Key | 16 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/17/2025 |
| Sample type | Aggregate Prequalification Program | A brief description of the sample | Washed Concrete Sand |
| The quantity of what the sample constitutes | Stockpile | From where was the sample collected | Source |
| First name of sampler or witnessed by | Carlos | Last name of sampler or witnessed by | Paredes |
| Title of sampler | QC Operations Supervisor | Telephone number of sampler | 6614772107 |
| Laboratory sample identification | 1509219927 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Granite Construction Solari Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-15-0114 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-01-17-16
DIME Test ID: 2025-01-17-16-2
Testing Lab: Granite Construction Company - Santa Paula
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-02-18
Test Results
Number of tests: 3
Input Type: Calculated
Tester's full name: Carlos Paredes
Date of test: 01/17/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.6
Sand reading (test 1): 3.9
Clay reading (test 2): 4.5
Sand reading (test 2): 3.7
Clay reading (test 3): 4.9
Sand reading (test 3): 4.2
Sand equivalent (test 1): 85
Sand equivalent (test 2): 83
Sand equivalent (test 3): 86
Sand equivalent before temperature correction: 85
Sand equivalent after temperature correction: 85
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/18/2025 ✔