Summary for Test 2017-09-13-9-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/13/2017 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing09/15/2017 Sample typeStock
A brief description of the sample1-8 x 5 1/2 bolt assembly 3/4-10 x2 1/2 bolt The quantity of what the sample constitutes6
From where was the sample collectedDistributor First name of sampler or witnessed byAmy
Last name of sampler or witnessed byBihary Title of samplerUnknown
Telephone number of sampler(216) 447-0165 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHodell-Natco Industries
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)3513-091217, 504194
Heat Number(s)100884204, DL16105991, 170233 Nut Mfg. Lot Number(s)387906C, 761086
Washer Mfg. Lot Number(s)0517-523, 774463 Bolt SpecificationA325
Bolt Length(s)5 1/2, 2 1/2 Nut SpecificationA563 DH
Washer SpecificationF436 FinishHDG
Diameter/Size1-8, 3/4-10 Bolt Mfg. Lot Number785345, 776147, 384870A, 741884
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s)

Test Details

DIME Sample ID: 2017-09-13-9
DIME Test ID: 2017-09-13-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-09-27

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/19/2017
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11ANA1\"87876390.910A325Brian

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 9/20/2017