Summary for Test 2025-01-20-3-2

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/20/2025 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/20/2025
Sample typeAggregate Prequalification Program A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes1 50lb bucket of washed concrete sand From where was the sample collectedSource
First name of sampler or witnessed byJustin Last name of sampler or witnessed byYettou
Title of samplerQC Technician Telephone number of sampler619-592-9623
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta - Santee Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)N/A
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-01-20-3
DIME Test ID: 2025-01-20-3-2
Testing Lab: Martin Marietta
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2025-02-19

Test Results


What size aggregate is being tested?: Fine Aggregate
Input Type: Calculated
Tester's full name: Austin Hill
Date of test: 02/19/2025
Percentage Loss of material retained on #8 sieve: 1.3 %
Percentage Loss of material retained on #16 sieve: 0.7 %
Percentage Loss of material retained on #30 sieve: 1.1 %
Percentage Loss of material retained on #50 sieve: 0.4 %
Percentage Loss of material retained on #100 sieve: 0.3 %
Weighted Average Percent Loss of Fine Aggregate: 3.8 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
Caltrand DIME Testing 2025pdf101.84 KB02/19/20252025-01-20-3-2   Info

Test was verified on 2/19/2025