Summary for Test 2025-02-11-4-2

Test performed: CTM 216-June 2011

Project Information

Project IdentifiersProject ID: 1000209
DEA: 07352304
EFIS: 0718000220
DIST-CO-RTE-PM07-LA-5-R60.0/R75.0
Award Date06/03/2024
Closeout DateNot set
Work DescriptionREPLACE DRAINAGE SYSTEMS, INSTALL GSRD, AND REPLACE SAND SHED.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR CASTAIC FROM 0.5 MILE NORTH OF LAKE HUGHES ROAD TO 0.5 MILE NORTH OF VISTA DEL LAGO ROAD
QA Service Level1 (Verified on 04/22/2024)

Sample Information

Sample Taken Date02/11/2025 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing02/11/2025 Sample typeAcceptance
A brief description of the sample Aggregate Base The quantity of what the sample constitutes4320 SF
From where was the sample collectedJob Site First name of sampler or witnessed byMichelangelo
Last name of sampler or witnessed bySese Title of samplerTET
Telephone number of sampler310-345-6204 Laboratory sample identification25-0556
Linked DIME Sample ID The fabricator/manufacturer/facility nameNA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleAggregate Base
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedVarious locations
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2025-02-11-4
DIME Test ID: 2025-02-11-4-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2025-02-12

Test Results


Is oversize material: Yes
Input Type: Measured
Tester's full name: Michelangelo Sese
Date of test: 02/11/2025
In-place wet density: 2.41
Percentage passing 3/4 in. sieve: 90 %
Percentage retained on 3/4 in. sieve: 10 %
Specific gravity of material passing 3/4 in. sieve: 2.26
Specific gravity of material retained on 3/4 in. sieve: 13.14 %
% Moisture: 4.8 %
Optimum Moisture: no data
Coefficient for 3/4 in. aggregate: 1.00
Corrected density: 2.46
Relative compaction: 98
General comments (publicly viewable) (Max 1000 characters): NB Rte. 5 north of Templin Hwy Location 7 - Castaic Sand Shed Building

Test was verified on 2/12/2025 ✔