Summary for Test 2025-01-15-24-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 993141
DEA: 060V1204
EFIS: 0616000207
DIST-CO-RTE-PM06-MAD-99-R6.9/R7.6
Award Date06/22/2022
Closeout Date12/02/2025
Work DescriptionCottonwood Creek Bridge Replacement - REPLACE BRIDGES AND CONSTRUCT RETAINING WALLS.
Location DescriptionMADERA COUNTY NEAR MADERA FROM 0.4 MILE SOUTH OF COTTONWOOD CREEK BRIDGE TO 0.1 MILE NORTH OF AVENUE 12 OVERCROSSING
QA Service Level1 (Verified on 07/28/2021)

Sample Information

Sample Taken Date01/15/2025 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/16/2025
Sample typeQuality Assurance A brief description of the sampleBarrier Rail concrete
The quantity of what the sample constitutes19 CY From where was the sample collectedJob Site
First name of sampler or witnessed byJuan Last name of sampler or witnessed byDe La Torre
Title of samplerASR Telephone number of sampler559-363-0082
Laboratory sample identification004 Linked DIME Sample ID
The fabricator/manufacturer/facility nameBuilders Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier41-0089S
Structure nameNBOR Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberND10531
The truck number from where the sample was collected9134 The batch plant ticket number from where the sample was collected1369640
Concrete batch plantSanger The fabricator/manufacturer designation for the sampleBuilders
A detailed description of where the material sample was collectedTail gate Where the material sample would have been placed if not sampledNBOR left barrier rail
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-01-15-24
DIME Test ID: 2025-01-15-24-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-02-12

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Gurjeet Litt
Date of test: 02/12/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 56080 lb
Maximum load on cylinder 2: 62830 lb
Maximum load on cylinder 3: 60070 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 4461.4 psi
Compressive strength of cylinder 2: 4998.4 psi
Compressive strength of cylinder 3: 4778.8 psi
Compressive strength (to nearest 10 psi): 4750 psi
General comments (publicly viewable) (Max 1000 characters): Required strenght 3600 psi @ 28 days

Test was verified on 2/12/2025