Summary for Test 2017-09-11-10-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 211966 DEA: 081G7004 |
---|---|
DIST-CO-RTE-PM | 08-SBD-38-26.0/31.0 |
Award Date | 03/13/2017 |
Closeout Date | 06/23/2021 |
Work Description | REPAIR FIRE DAMAGE, EXISTING EMBANKMENT, AND DRAINAGE SYSTEM. |
Location Description | SAN BERNARDINO COUNTY NEAR BIG LAKE CITY FROM 0.5 MILE WEST OF GLASS ROAD TO 0.2 MILE EAST OF SEVEN OAKS ROAD. |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 09/11/2017 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/13/2017 |
Sample type | Quality Control | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | biggen | Last name of sampler or witnessed by | raney |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 966-02 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | robertsons | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | sc590b6a |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | np |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | np | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2017-09-11-10
DIME Test ID: 2017-09-11-10-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-09-18
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 09/18/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 97345 lb
Maximum load on cylinder 2: 98380 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 3443.4 psi
Compressive strength of cylinder 2: 3480.0 psi
Compressive strength (to nearest 10 psi): 3460 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/18/2017 ✔